LM-Biotech – Hoses

Silicone Hose – Unassembled

Standard Sizes:
· DIN DN04 – DIN DN10
· ISO DN10 – ISO DN50
Material:
· Medium Contacted: Silicone Platinum Cured
· Non-medium Contacted: Glass Silk or Aramid (Keflar)
Surface Quality:
· Medium Contacted: Internal surface Ra < 0.2 μm
Traceability: Product contacted material marked with material no. and heat no.
Media: Gases and liquids
Operating Temperature: -40°C to +180°C at ambient pressure
Operating Pressure: 0.3 to 16 bar at ambient temperature, pulsing pressure prohibited.
Certification: Medium contacted: FDA conformity, USP-Class VI, TSE Free

Available in:
· Type SIS: Silicone Hose without Reinforcement
· Type SGB: Silicone Hose Glass Silk Reinforced
· Type SAB: Silicone Hose Aramid Reinforced
· Type SDA: Silicone Hose Double Aramid Reinforced

Silicone Hose with Aseptic End according to DIN 11864

Standard Sizes:
· DIN DN04 – DIN DN10
· ISO DN10 – ISO DN50
Material:
· Medium Contacted: Silicone Platinum Cured, 1.4435 BN2 (316L), Special materials e.g. Hastelloy, Titan, 1.4539 etc. on request
· Non-medium Contacted: 1.4305 or equivalent
Surface Quality:
· Medium Contacted: Internal surface Ra < 0.2 μm, electropolished Ra < 0.6 μm, other qualities on request
· Non medium Contacted: Electro polished Ra > 1.6 μm
Traceability: Product contacted material marked with material no. and heat no.
Media: Gases and liquids – pulsating pressure and permanent steam are prohibited.
Operating Temperature:
· Type SIS: -40°C to +160°C at ambient pressure
· Type SGB/SAB/SDA: -40°C to +180°C at ambient pressure
Operating Pressure: 0.3 to 16 bar at ambient temperature, pulsing pressure prohibited.
Certification:
· Medium contacted: EN 10204 / 3.1
· Hose: FDA conformity, USP-Class VI, TSE Free

Available in:
· Hose with Aseptic Liner according to DIN 11864-1
· Hose with Aseptic Flange Male according to DIN 11864-2
· Hose with Aseptic Flange Female according to DIN 11864-2
· Hose with Aseptic Clamp Ferrule Male according to DIN 11864-3
· Hose with Aseptic Clamp Ferrule Female according to DIN 11864-3

Silicone Hose with Clamp according to DIN 32676

Standard Sizes:
· DIN DN04 – DIN DN10
· ISO DN10 – ISO DN50
Material:
· Medium Contacted: Silicone Platinum Cured, 1.4435 BN2 (316L), Special materials e.g. Hastelloy, Titan, 1.4539 etc. on request
· Non-medium Contacted: 1.4305 or equivalent
Surface Quality:
· Medium Contacted: Internal surface Ra < 0.2 μm, electropolished Ra < 0.6 μm, other qualities on request
· Non medium Contacted: Electro polished Ra > 1.6 μm
Traceability: Product contacted material marked with material no. and heat no.
Media: Gases and liquids – pulsating pressure and permanent steam are prohibited.
Operating Temperature:
· Type SIS: -40°C to +160°C at ambient pressure
· Type SGB/SAB/SDA: -40°C to +180°C at ambient pressure
Operating Pressure: 0.3 to 16 bar at ambient temperature, pulsing pressure prohibited.
Certification:
· Medium contacted: EN 10204 / 3.1
· Hose: FDA conformity, USP-Class VI, TSE Free

Available in:
· Hose with Clamp according to DIN 32676

Silicone Hose with Sterile Connection Bioplus

Standard Sizes:
· DIN DN04 – DIN DN10
· ISO DN10 – ISO DN50
Material:
· Medium Contacted: Silicone Platinum Cured, 1.4435 BN2 (316L), Special materials e.g. Hastelloy, Titan, 1.4539 etc. on request
· Non-medium Contacted: 1.4305 or equivalent
Surface Quality:
· Medium Contacted: Internal surface Ra < 0.2 μm, electropolished Ra < 0.6 μm, other qualities on request
· Non medium Contacted: Electro polished Ra > 1.6 μm
Traceability: Product contacted material marked with material no. and heat no.
Media: Gases and liquids – pulsating pressure and permanent steam are prohibited.
Operating Temperature:
· Type SIS: -40°C to +160°C at ambient pressure
· Type SGB/SAB/SDA: -40°C to +180°C at ambient pressure
Operating Pressure: 0.3 to 16 bar at ambient temperature, pulsing pressure prohibited.
Certification:
· Medium contacted: EN 10204 / 3.1
· Hose: FDA conformity, USP-Class VI, TSE Free

Available in:
· Hose with Sterile Ferrule Bioplus-S
· Hose with Sterile Flange Male Bioplus-F
· Hose with Sterile Flange Female Bioplus-F
· Hose with Sterile Clamp Male Bioplus-C
· Hose with Sterile Clamp Female Bioplus-C

Silicone Hose with Weld End

Standard Sizes:
· DIN DN04 – DIN DN10
· ISO DN10 – ISO DN50
· BSOD 1/4″ – BSOD 2″
Material:
· Medium Contacted: Silicone Platinum Cured, 1.4435 BN2 (316L), Special materials e.g. Hastelloy, Titan, 1.4539 etc. on request
· Non-medium Contacted: 1.4305 or equivalent
Surface Quality:
· Medium Contacted: Internal surface Ra < 0.2 μm, electropolished Ra < 0.6 μm, other qualities on request
· Non medium Contacted: Electro polished Ra > 1.6 μm
Traceability: Product contacted material marked with material no. and heat no.
Media: Gases and liquids – pulsating pressure and permanent steam are prohibited.
Operating Temperature:
· Type SIS: -40°C to +160°C at ambient pressure
· Type SGB/SAB/SDA: -40°C to +180°C at ambient pressure
Operating Pressure: 0.3 to 16 bar at ambient temperature, pulsing pressure prohibited.
Certification:
· Medium contacted: EN 10204 / 3.1
· Hose: FDA conformity, USP-Class VI, TSE Free

Available in:
· Silicone Hose with Weld End